EA-11-251 · CAL · Issued 2011-12-27 · Reactor Licensees
Action
EA Number
EA-11-251
Licensee
NOV (White)
Category
Reactor Licensees
Action type
CAL
Date issued
2011-12-27
Description
On December 27, 2011, the NRC issued a Notice of Violation to Carolina Power and Light Company for a violation of Title 10 of the Code of Federal Regulations, Part 50, Appendix B, Criterion XVI, “Corrective Action,” associated with a White Significance Determination Process finding involving the failure of Brunswick personnel to promptly identify and correct a condition adverse to quality involving the external flood barrier for the emergency diesel generator fuel oil tank rooms as of April 20, 2011. Specifically, the entrance enclosures which house the emergency diesel generator fuel oil tanks had several openings, unsealed pinholes, and a narrow gap along the perimeter of the base walls, which would allow water intrusion into the emergency diesel generator fuel oil tank rooms during a design basis external event (hurricane).